Build volume
220 x 220 x 250 mm advertised
Advertised dimensions; check usable space and variants.
Sources & dates
- Sovol SV06 technical data table · 2026-08 · vendor
Open-source i3-style bedslinger kit with an all-metal planetary direct-drive extruder, now replaced in Sovol's line by the SV06 ACE.
220 x 220 x 250 mm advertised
Advertised dimensions; check usable space and variants.
300 °C claimed
Published limits; hardware and firmware limits may differ.
Not recorded in this catalog.
Dated listing, not a live offer. Read the configuration and region.
Understand the hardware, explore compatible changes and find a diagnostic starting point when something goes wrong. Expand the specification sections for every recorded value, condition and original reference.
Dimensions, construction and the hardware that moves the print.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Manufacturer & exact marketed model name (verify the exact product identity first) | Sovol SV06 | 1 source
|
| Variants & sibling models — and how to tell them apart (spec-contamination risk) | Base model of a four-way family: SV06 (220x220x250, Marlin-era silent board), SV06 Plus (300x300x340), SV06 ACE and SV06 Plus ACE (both Klipper, ceramic hotend, camera, 4.3-inch touchscreen). ACE specs must not be applied to the non-ACE machines | 3 sources
|
| Market position: superseded? successor announced? | No longer listed on Sovol's own store: the current 3D-printer collection contains only SV08, SV08 Max, Zero, SV06 ACE and SV06 Plus ACE. 3DJake also shows it sold out and delisted. Superseded by the SV06 ACE | 2 sources
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Build volume X×Y×Z (mm) — advertised vs actually usable | 220 x 220 x 250 mm advertised | 1 source
|
| Frame construction & material | Open i3-style frame, supplied as an assembly kit | 1 source
|
| Enclosure: open / enclosed; panel material; door/lid | Open frame, no enclosure | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Kinematics (bedslinger i3 / CoreXY / other) | Cartesian i3 bedslinger | 1 source
|
| Z-axis: leadscrew count & type, sync mechanism, anti-backlash | Dual Z-axis motors | 1 source
|
| Stepper drivers (exact model e.g. TMC2209; UART/SPI; sensorless homing?) | TMC2209 drivers on a 32-bit silent board (Sovol description, not verified against a board photo) | 1 source
|
Extrusion, heating, leveling and material handling.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Type (direct drive / bowden) & design name | All-metal direct-drive extruder with planetary gear reduction | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Hotend design (proprietary/standard; quick-swap mechanism?) | All-metal hotend rated to 300 °C. MK8-style nozzle | 1 source
|
| Max nozzle temp claimed AND firmware max temp limit (both values) | 300 °C claimed | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Bed surface (material, texture, coating), single/double-sided | Flexible PEI build surface | 1 source
|
In this conversion, PRINT_START fails when KAMP is disabled and no default mesh exists. Check that combination before changing hardware; when using KAMP instead, enable object labels in the slicer as the maintainer requires.
Applies to: SV06 master branch in bassamanator’s Klipper configuration; this is a conversion-specific macro condition, not a stock Marlin fault.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Auto bed leveling: probe technology (inductive / strain gauge / load cell / touch probe) | Automatic levelling over 25 points; probe technology not stated on the listing | 1 source
|
| Mesh grid size (probe point count — firmware evidence) | 25 points (manufacturer claim) | 1 source
|
This rear-mounted duct adapts a 5015 blower to the SV06 toolhead. The creator supplies CAD and fitting instructions, including longer M3 mounting screws and an adjustable duct height.
Applies to: SV06; requires the matching 5015 fan and wiring. Check nozzle clearance and select a documented revision; the creator labels V5 untested.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Officially supported filament list | 1.75 mm filament; Sovol does not publish a per-material list for this model beyond the 300 °C hotend rating | 1 source
|
Firmware, controls, connections and calibration.
This configuration supplies an SV06 firmware route, print-start macros and gantry calibration for an external Klipper host. It also documents MCU identification, slicer setup and first configuration checks.
Applies to: Stock Sovol SV06 uses the master branch; replacement SKR and Fly boards have different branches. Requires a Linux host and data USB cable.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| WiFi (band/standard), Ethernet, USB ports, SD/flash-drive | USB connection; micro-SD card. No Wi-Fi | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Power-loss recovery: mechanism (how is state saved? capacitor / eeprom / file on shutdown?) | Resume-after-power-loss supported; mechanism not published | 1 source
|
This guide presents the catalog’s sourced record for this exact model. Source dates belong to each reference; a page update does not mean every specification has been rechecked.
Prices are dated listing snapshots, with configuration, regional and sale conditions. They are not current offers. Unknown values remain unfilled.
Firmware, variants and available accessories can change. Read the original reference before making a purchase or planning a process.
Firmware, modifications and troubleshooting links are checked against the model and stated hardware or firmware revision. A creator’s compatibility claim is not a fit test by this site. Official troubleshooting describes a diagnostic route; individual reports do not establish a failure rate.
This review did not verify hardware upgrades for this exact model. That is a research gap, not a claim that none exist.