Where it is used
Outdoor structural parts, drone and antenna mounts where stiffness and UV stability both matter
Sources
- Bambu Filament Technical Data Sheet V1.0 — ASA-CF · 2026-08 · tds
- CarbonX Carbon Fiber ASA Technical Data Sheet · 2026-08 · tds
ASA with chopped carbon fibre: Young's modulus rises from 2450 to 4200 MPa and HDT from 100 to 110 °C, while notched Charpy falls to a third and a hardened nozzle becomes mandatory.
Open in interactive comparisonOutdoor structural parts, drone and antenna mounts where stiffness and UV stability both matter
ASA with chopped carbon fibre: Young's modulus rises from 2450 to 4200 MPa and HDT from 100 to 110 °C, while notched Charpy falls to a third and a hardened nozzle becomes mandatory.
ASA-CF combines the outdoor durability of ASA with increased stiffness and dimensional stability. The category is relevant to exposed mechanical mounts and structural fittings where deflection matters more than elastic compliance. 3DXTech markets CarbonX ASA+CF for high-modulus outdoor structural components, and its matte surface is useful on visible equipment parts.
The tradeoff is reduced tolerance for impact and concentrated strain, not a universal improvement over ordinary ASA. Bambu’s grade comparison shows substantially lower notched impact resistance, while the composite remains direction-dependent across layers. Carbon reinforcement also does not establish ESD performance. Use the actual grade’s properties and mount geometry rather than transferring strength or fibre content between manufacturers.
FDM · 3DXTech CarbonX ASA+CF; 15% carbon fibre on the source page · Manufacturer-listed applications
3DXTech explicitly combines outdoor suitability with high modulus and dimensional stability for CarbonX ASA+CF. It does not identify a particular customer mount or establish a load rating for arbitrary printed geometry.
Check the model’s material and process notes before choosing a filament.
Representative catalog values. Check the exact grade and its linked conditions before using a setting.
250–280 (Bambu Lab)
250–280 (Bambu Lab)
80–100 (Bambu Lab)
80–100 (Bambu Lab)
Enclosure recommended
Enclosure recommended — Bambu Lab specifies a 45–60 °C chamber
80 °C for 8 h (Bambu Lab)
80 °C for 8 h (Bambu Lab)
Open a topic to explore the complete data. Each value keeps its original conditions, units and dated sources.
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Base polymer / chemistry | ASA reinforced with chopped carbon fibre — Formfutura's ApolloX CF10 is 10 wt% | 3 sources
|
| Density (g/cm³) | 1.02 (Bambu Lab), 1.1 (Formfutura ApolloX CF10) and 1.11 (3DXTech), ISO 1183 | 3 sources
|
| Typical price (USD/kg) | 1 kg spools cluster near 37 | 2 sources
|
| Price range across brands (USD/kg) | 25–90 across brands; IEMAI 25, Ambrosia 33, Bambu Lab 37, Polymaker Fiberon 40, 3DXTech 90 | 5 sources
|
| Market availability (1–5) | Available from several mainstream brands | 4 sources
|
| Spool sizes & diameters | 1.75 and 2.85 mm; 0.5, 0.75 and 1 kg spools | 3 sources
|
| Typical applications | Outdoor structural parts, drone and antenna mounts where stiffness and UV stability both matter | 2 sources
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Nozzle temperature (°C) | 250–280 (Bambu Lab) | 1 source
|
| Bed temperature (°C) | 80–100 (Bambu Lab) | 1 source
|
| Enclosure / chamber requirement (1–5) | Enclosure recommended — Bambu Lab specifies a 45–60 °C chamber | 2 sources
|
| Recommended chamber temperature (°C) | 45–60 (Bambu Lab) | 1 source
|
| Part cooling fan | Fan on (Bambu Lab) | 1 source
|
| Bed surface & adhesion aid | PEI sheet, BuildTak or an adhesion aid such as Magigoo (Polymaker); Simplify3D also lists Kapton tape and ASA slurry | 2 sources
|
| Maximum volumetric flow (mm³/s; see test conditions) (mm³/s) | 20 at Bambu Lab's 250 mm/s cap on a 0.4 mm nozzle at 0.2 mm layer | 2 sources
|
| Warping tendency (1–5) | Moderate — needs adhesion aid or draught shield; the fibre reduces warping against unfilled ASA | 1 source
|
| Bed-adhesion difficulty (1–5) | Needs a specific surface plus adhesive | 1 source
|
| Stringing / oozing tendency (1–5) | Slight — Polymaker advises 1–2 mm retraction at 20–30 mm/s | 1 source
|
| Overall printing difficulty (1–5) | Intermediate — dry filament and a tuned profile; hardened nozzle mandatory | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Nozzle hardness required (1–4) | Hardened steel required | 1 source
|
| Abrasiveness (1–5) | Highly abrasive — standard CF composite | 1 source
|
| Nozzle clog risk (1–5) | Moderate — needs dry filament and a clean nozzle; Prusa lists higher risk of nozzle clogging for fibre-filled composites and Simplify3D a higher tendency to clog | 2 sources
|
| Heat-creep / jam sensitivity (1–5) | Slightly sensitive | 1 source
|
| Hotend requirement | No special hotend required | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Moisture absorption (hygroscopicity) (1–5) | Moderate — 0.33 % saturated at 25 °C / 55 % RH (Bambu Lab) | 1 source
|
| Equilibrium moisture content at ~50 % RH (%) | 0.33 saturated at 25 °C / 55 % RH (Bambu Lab) | 1 source
|
| Drying temperature & time | 80 °C for 8 h (Bambu Lab) | 1 source
|
| Symptoms when wet | Bubbling and popping at the nozzle, stringing and a rough surface | 1 source
|
| Effect of moisture on strength | No dry-versus-conditioned figures are published; Polymaker groups the styrenics as moderate-sensitivity and absorbed water shows as bubbling and poor layer adhesion | 1 source
|
| Storage requirement | Sealed with desiccant; Polymaker rates the styrenics moderate-sensitivity | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Tensile strength (XY) (MPa) | 34 ± 3 printed XY, ISO 527 (Bambu Lab); 3DXTech quotes 48 at break and Formfutura 79 at 23 °C | 3 sources
|
| Young's modulus (MPa) | 4200 ± 270 printed XY, ISO 527 (Bambu Lab); 3DXTech quotes 5355 and Formfutura 7580 | 3 sources
|
| Elongation at break (%) | 9.6 ± 1.4 printed XY, ISO 527 (Bambu Lab); 3DXTech quotes 3 at break and Formfutura 1.8 | 3 sources
|
| Flexural strength (MPa) | 72 ± 5 printed XY, ISO 178 (Bambu Lab); 3DXTech quotes 78 | 2 sources
|
| Flexural modulus (MPa) | 3740 ± 130 printed XY, ISO 178 (Bambu Lab); 3DXTech quotes 5210 | 2 sources
|
| Charpy impact, notched (kJ/m²) | 6.2 ± 1.4 printed XY, ISO 179, notched (Bambu Lab) — a third of unfilled Bambu Lab ASA's 19.6 | 2 sources
|
| Other impact data | Charpy unnotched 14.0 ± 2.2 printed XY (Bambu Lab, ISO 179), against 41.0 for unfilled Bambu Lab ASA | 2 sources
|
| Layer adhesion / Z tensile (MPa) | 30 ± 4 printed Z, ISO 527 (Bambu Lab); flexural Z falls to 33 against 72 in XY | 1 source
|
| Brittleness (1–5) | Brittle — snaps with little warning | 2 sources
|
| Creep resistance / sustained load (1–5) | Good — no creep test found; chopped carbon fibre lifts modulus to 4200 MPa against 2379–2450 for unfilled ASA | 2 sources
|
| Fatigue / repeated-flex resistance (1–5) | Below average — no CF-grade S-N curve; notched Charpy falls to 6.2 kJ/m² against 19.6 for unfilled Bambu Lab ASA | 2 sources
|
| Elasticity / flexibility (1–5) | Rigid | 1 source
|
| Z strength as % of XY (%) | 88 by tensile, 46 by flexural (printed, Bambu Lab) | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| HDT at 0.45 MPa (°C) | 110 (ISO 75, 0.45 MPa, Bambu Lab) against 100 for unfilled Bambu Lab ASA | 2 sources
|
| HDT at 1.8 MPa (°C) | 102 (ISO 75, 1.8 MPa, Bambu Lab) against 92 for unfilled Bambu Lab ASA | 2 sources
|
| Continuous service temperature (°C) | 93 — Prusa publishes this as the temperature resistance of Prusament ASA | 1 source
|
| Flammability / UL 94 | Flammable; no UL 94 rating published | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| UV resistance (1–5) | Excellent — designed for permanent outdoor use; the acrylate rubber phase is unchanged by the fibre | 2 sources
|
| Chemical resistance | Good against weak acids, weak alkalis, oils and grease; dissolved by acetone | 1 source
|
| Food contact | Not food safe | 1 source
|
| Biodegradability / compostability | Not biodegradable | 1 source
|
| Recyclability | Not accepted in household plastic collection | 1 source
|
| Electrical & ESD properties | Surface resistance above 10⁹ ohm/sq — not static-dissipative (3DXTech, ASTM D257) | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Fume toxicity (1–5) | High — hazardous VOC such as styrene; enclosure and filtration needed | |
| Hazardous species emitted | Styrene. Bambu Lab states ABS and ASA release harmful gases such as styrene at printing temperature, which can be toxic and cause dizziness or nausea. Azimi et al. measured styrene from every styrenic filament tested but did not test ASA itself | |
| Ventilation / filtration requirement (1–5) | Enclosure with carbon and HEPA filtration | |
| Dust & fibre handling hazard | Carbon fibre is bound in the matrix; sanding dust should not be inhaled | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Sanding & machining | Sands well and takes filler before painting | 1 source
|
| Painting & finishing | Paints readily; ASA holds colour outdoors so many parts are left unpainted | 1 source
|
| Gluing & solvent welding | Solvent-welds with acetone | 1 source
|
| Vapour / chemical smoothing | Acetone vapour smoothing works | 1 source
|
| Support material pairing | HIPS breaks away or dissolves in d-limonene; Bambu Lab sells a Support for ABS that also serves ASA | 1 source
|
| Dimensional accuracy & detail | Matte fibre-filled finish hides layer lines | 1 source
|
| Property and unit | Published value and conditions | Sources and dates |
|---|---|---|
| Soluble in | Acetone dissolves the resin and leaves the fibre; MEK, THF, ethyl acetate and chlorinated solvents attack the styrenic backbone. | 2 sources
|
| Softened or crazed by | Limonene attacks some grades — Prusa reports Prusament ASA Orange flaking apart as layer adhesion fails. | 1 source
|
| Solvent welding & smoothing agent | Acetone vapour reaches only the resin fraction, so the fibre is left standing proud of the smoothed surface. | 2 sources
|
Values describe representative grades, not every spool. Manufacturer datasheets and independent tests retain their source labels and dates. Printed orientation, test method, conditioning and formulation can change results. Unknown values are —. A listed use is not a certification. Shore A, Shore D and Rockwell hardness are separate scales.
Historical USD/kg snapshots. Read each listing’s sale/from qualifiers, spool mass, source date, shipping and tax notes. Product figures are separate from the material summary.
$25.00 / 1 kg spool, store.iemai3d.com, Aug 2026 (regular price $26.00)
Hardened steel nozzle required. TDS gives XY and Z figures separately.
Open product listing ↗| Density (g/cm³) | 1.02 (ISO 1183) |
|
|---|---|---|
| Nozzle temperature (°C) | 240-260 |
|
| Equilibrium moisture content at ~50 % RH (%) | 0.33 (saturated at 25 C, 55 % RH) |
|
| Tensile strength (XY) (MPa) | 34 +/- 3 (printed XY, ISO 527) |
|
| Young's modulus (MPa) | 4200 +/- 270 (printed XY, ISO 527) |
|
| Elongation at break (%) | 9.6 +/- 1.4 (printed XY, ISO 527) |
|
| Flexural strength (MPa) | 72 +/- 5 (printed XY, ISO 178) |
|
| Flexural modulus (MPa) | 3740 +/- 130 (printed XY, ISO 178) |
|
| Charpy impact, notched (kJ/m²) | 6.2 +/- 1.4 (printed XY, ISO 179, notched) |
|
| Layer adhesion / Z tensile (MPa) | 30 +/- 4 (printed Z, ISO 527) |
|
| HDT at 0.45 MPa (°C) | 110 (ISO 75, 0.45 MPa) |
|
| HDT at 1.8 MPa (°C) | 102 (ISO 75, 1.8 MPa) |
|
| Glass transition (Tg) (°C) | 105 (DSC) |
|
$32.99 / 1 kg spool; $44.99 for the 2 kg variant = $22.50/kg, filastruder.com, Aug 2026
Handle ambrosia-asa-cf-filament.
Open product listing ↗| Density (g/cm³) | 1.09–1.10 (ISO 1183) | |
|---|---|---|
| Spool sizes & diameters | 1 kg and 2 kg spools; 1.75 mm | |
| Diameter tolerance (± mm) | 0.03 | |
| Nozzle temperature (°C) | 250–280 (Ambrosia recommends 270) | |
| Bed temperature (°C) | 100–120 (Ambrosia recommends 110) | |
| Recommended chamber temperature (°C) | 40–120 (Ambrosia recommends 45) | |
| Part cooling fan | 0–70 %, depending on cooling capability | |
| Tensile strength (XY) (MPa) | 39–42 (ISO 527; specimen type not stated) | |
| Elongation at break (%) | 15.5–17.5 (ISO 527; specimen type not stated) | |
| Flexural strength (MPa) | 80–82.5 (ISO 178; specimen type not stated) | |
| Flexural modulus (MPa) | 850–900 (specimen type not stated) | |
| Other impact data | Izod impact 10.5–12 kJ/m² (ISO 180; specimen type not stated) | |
| HDT at 0.45 MPa (°C) | 88 (ISO 75, 0.455 MPa) |
$36.99 / 1 kg spool, us.store.bambulab.com, Aug 2026
Young's modulus 4200 MPa against 2450 unfilled; notched Charpy drops from 19.6 to 6.2 kJ/m².
Open product listing ↗| Density (g/cm³) | 1.02 (ISO 1183) |
|
|---|---|---|
| Young's modulus (MPa) | 4200 ± 270 (printed XY, ISO 527) |
|
| Charpy impact, notched (kJ/m²) | 6.2 ± 1.4 (printed XY, ISO 179, notched) |
|
| HDT at 0.45 MPa (°C) | 110 (ISO 75, 0.45 MPa) |
|
$19.99 / 0.5 kg spool = $39.98/kg, Polymaker product catalogue, Aug 2026
Handle fiberon-asa-cf08.
Open product listing ↗| Base polymer / chemistry | ASA with 8 % chopped carbon fibre |
|
|---|---|---|
| Density (g/cm³) | 1.09 at 23 °C (ISO 1183) |
|
| Nozzle temperature (°C) | 260–280 |
|
| Bed temperature (°C) | 90–100 |
|
| Part cooling fan | Off |
|
| Nozzle hardness required (1–4) | Hardened steel required — brass nozzle life about 9 h |
|
| Equilibrium moisture content at ~50 % RH (%) | 0.37 equilibrium water absorption |
|
| Drying temperature & time | 90 °C for 6 h |
|
| Tensile strength (XY) (MPa) | 43.5 ± 0.7 (printed XY, ISO 527, 270 °C nozzle, 100 % infill) |
|
| Young's modulus (MPa) | 3612 ± 181 (printed XY, ISO 527) |
|
| Elongation at break (%) | 1.8 ± 0.1 (printed XY, ISO 527); 2.7 printed Z |
|
| Flexural strength (MPa) | 69.1 ± 1.6 (printed XY, ISO 178) |
|
| Flexural modulus (MPa) | 3265 ± 57 (printed XY, ISO 178) |
|
| Charpy impact, notched (kJ/m²) | 5.5 ± 0.14 (printed XY, notched, ISO 179) |
|
| Layer adhesion / Z tensile (MPa) | 25.0 ± 0.4 (printed Z, ISO 527) |
|
| HDT at 0.45 MPa (°C) | 103.0 (ISO 75, 0.45 MPa) |
|
| HDT at 1.8 MPa (°C) | 97.3 (ISO 75, 1.8 MPa) |
|
| Glass transition (Tg) (°C) | 106.6 (DSC) |
|
| Melting point / Vicat (°C) | Vicat 110.8 (ISO 306) |
|
| Flammability / UL 94 | UL 94 HB at 1.5 mm |
|
| Electrical & ESD properties | Surface resistivity >10^12 Ω (ANSI/ESD S11.11) — insulating |
|
$67.50 / 750 g spool = $90.00/kg, 3dxtech.com product catalogue, Aug 2026
Handle carbonx-asa-cf-1. Tensile modulus 5355 MPa, the stiffest here.
Open product listing ↗| Density (g/cm³) | 1.11 (ISO 1183) |
|
|---|---|---|
| Nozzle temperature (°C) | 250 (TDS printed-specimen condition) |
|
| Bed temperature (°C) | 110 (TDS printed-specimen condition) |
|
| Tensile strength (XY) (MPa) | 48 at break (ISO 527) |
|
| Young's modulus (MPa) | 5355 (ISO 527) |
|
| Elongation at break (%) | 3 at break (printed XY, ISO 527) |
|
| Flexural strength (MPa) | 78 (printed XY, ISO 178) |
|
| Flexural modulus (MPa) | 5210 (printed XY, ISO 178) |
|
| HDT at 0.45 MPa (°C) | 97 (ISO 75, 0.45 MPa) |
|
| Glass transition (Tg) (°C) | 105 (DSC) |
|
| Electrical & ESD properties | Surface resistance >10^9 Ω/sq (ASTM D257) |
|