Filament comparison
PEI 1010 vs PLA HS
Compare printing settings, strength, heat resistance, dated prices and sources.
2 selected · all documented properties
| Property | PEI (ULTEM 1010)HIGHTEMP | High-Speed PLAPLA |
|---|---|---|
| Market snapshot | ||
| Listing priceUSD/kg; dated snapshots | $281.22/kg median; $195.00–$698.00/kg across 6 dated product listings | $19.99/kg median; $11.49–$32.99/kg across 10 dated product listings |
| Identity & Market | ||
| Base polymer / chemistry | Polyetherimide, ULTEM 1010 grade — the higher-temperature, food- and medical-contact PEI[1][2] | PLA with rheology and crystallisation tuned for high volumetric flow; melt index 15.4 g/10 min vs 7–11 for standard PLA[3][4] |
| Densityg/cm³ | 1.27 (ISO 1183, 3DXTech and Prusament); 1.29 specific gravity on moulded plaques (ASTM D792, Stratasys)[1][2][5] | 1.23 (ISO 1183, at 21.5 °C)[3] |
| Typical priceUSD/kg | 1 kg-equivalent spools span 195–698; the middle of the market is about 270[6][7][8][9][10] | Mainstream 1 kg spools cluster near 20[11][12][13] |
| Price range across brandsUSD/kg | 195-698 across brands and grades; 3DXTech ThermaX PEI 1010 195 at 2 kg, IEMAI 3D 223 at 1 kg, 3D4Makers 270 at 2 kg, Prusament 292 at 500 g, Kimya 347 at 500 g, 3DXTech ESD-PEI 1010 698 at 500 g[6][7][8][9][10] | 11–33 across brands; budget house brands 11–18, Prusament 33[14][15][16] |
| Market availability1–5 | Niche, a handful of specialist brands[6][7][8][9] | Stocked by most mainstream brands[17][13][18] |
| Spool sizes & diameters | 1.75 and 2.85 mm; 200 g to 2 kg spools, plus Stratasys canisters[6][9][5] | 1.75 mm; 1 kg spools[11][13] |
| Typical applications | Autoclavable tooling, food-contact fixtures and parts that must hold load near 200 °C[2] | Large or repetitive prints on printers that can sustain high flow[19][17] |
| Diameter tolerance± mm | Not documented | ±0.03 (Bambu Lab PLA Basic, rated to 258 mm/s)[20] |
| Printing Parameters | ||
| Nozzle temperature°C | 410 ± 10 (Prusament) — the hottest nozzle in the dataset[2] | 210–230 for high-speed work; 190–210 at classic speeds[3][17] |
| Bed temperature°C | 140–160 (Prusament); 130–140 (3DXTech)[2][1] | 30–60 (Polymaker); 35–45 (Bambu Lab)[3][21] |
| Enclosure / chamber requirement1–5 | Actively heated chamber required — Prusa specifies 90 °C[2] | Open frame is fine[3] |
| Recommended chamber temperature°C | 90 (Prusament)[2] | Not documented |
| Part cooling fan | Not documented | Fan on[3] |
| Bed surface & adhesion aid | PA nylon sheet or powder-coated sheet with high-temperature glue (Prusament)[2] | Not documented |
| Maximum volumetric flow (mm³/s; see test conditions)mm³/s | Not documented | ≈24 at 300 mm/s with a 0.4 mm nozzle and 0.2 mm layer; 30 % more flow than regular PLA at the same temperature[3][17][19][22] |
| Warping tendency1–5 | Severe — heated chamber needed[2] | None[3] |
| Bed-adhesion difficulty1–5 | Not documented | Sticks to anything[23] |
| Overall printing difficulty1–5 | Expert / industrial hardware only[2][24] | Easy — minor profile tuning; needs a printer that can actually reach the flow rate[17][3] |
| Extruder requirement | A hot end rated to 420 °C, a heated chamber and a high-temperature bed; Prusa dries the filament at 150 °C for 6–8 h before printing[2] | Not documented |
| Hardware Wear & Reliability | ||
| Nozzle hardness required1–4 | Brass fine indefinitely for unfilled grades, but brass softens near these nozzle temperatures — hardened or plated hot ends are the norm[2] | Brass fine indefinitely[25] |
| Abrasiveness1–5 | Non-abrasive when unfilled[1] | Non-abrasive[26][25] |
| Nozzle clog risk1–5 | Moderate — needs dry filament and a clean nozzle; 3DXTech lists no special nozzle concerns but a mandatory 150 °C pre-dry before every print[27] | Very low[25] |
| Heat-creep / jam sensitivity1–5 | Not documented | Moderate — good heatbreak cooling needed; PLA softens below 60 °C[28] |
| Hotend requirement | Not documented | No special hot-end required[23] |
| Moisture Behaviour | ||
| Moisture absorption (hygroscopicity)1–5 | Not documented | Moderate — 0.40 % equilibrium at 23 °C / 70 % RH[3] |
| Equilibrium moisture content at ~50 % RH% | 0.4 in 24 h and 0.7 in 7 days at 24 °C and 22 % RH (Prusament)[2] | 0.40 equilibrium at 23 °C / 70 % RH (Polymaker PolySonic)[3] |
| Drying temperature & time | 150 °C for 6–8 h (Prusament) — the hottest drying schedule in the dataset[2] | 55 °C for 6 h; 50 °C for 8 h (Bambu Lab)[3][21] |
| Symptoms when wet | Not documented | Bubbling and popping at the nozzle, stringing, rough surface and weak layers[29] |
| Effect of moisture on strength | No dry-versus-conditioned figures are published; 3DXTech mandates a 150 °C, 4 h pre-dry before every print because trapped water flashes to steam at these nozzle temperatures[27] | Polymaker rates PLA low-sensitivity — the loss shows as poor layer adhesion and brittle layers rather than a published strength figure[29] |
| Storage requirement | Not documented | Sealed with desiccant below 20 % RH; shelf life at ambient is long[21][23] |
| Mechanical Properties | ||
| Tensile strength (XY)MPa | 79-95 printed in plane: Stratasys 79.2 (F900 T14) to 91.6 (F3300 N500) at break in XZ, ASTM D638; Prusament 95 +/- 3.5 at yield printed horizontal, ISO 527-1; 3DXTech quotes 56 (ISO 527)[5][2][1] | 43.9 at 300 mm/s and 46.0 at 46.7 mm/s (printed XY, ISO 527); 58.6 on My Tech Fun bars for Creality Hyper PLA[3][30] |
| Young's modulusMPa | 2300-3040 printed in plane: Prusament 2300 +/- 100 horizontal (ISO 527-1), Stratasys 2920-3040 in XZ (ASTM D638); 3DXTech quotes 2500[5][2][1] | 2650 at 300 mm/s, 2878 at classic speed (printed XY, ISO 527)[3] |
| Elongation at break% | 4.0-4.1 at break in XZ (ASTM D638, Stratasys); Prusament gives 6.6 +/- 0.7 at yield printed horizontal (ISO 527-1); 3DXTech quotes 3[5][2][1] | 15.1 at 300 mm/s, 21.5 at classic speed (printed XY, ISO 527)[3] |
| Flexural strengthMPa | 128 at 5 % strain (F900 T14) and 144 at break (F3300) printed XZ, ASTM D790; Prusament 98 +/- 6.5 horizontal and 138 +/- 5.3 vertical (ISO 178); 3DXTech quotes 110[5][2][1] | 71.4 at 300 mm/s, 76.5 at classic speed (printed XY, ISO 178)[3] |
| Flexural modulusMPa | 2910-3260 printed XZ (ASTM D790, Stratasys); Prusament 2300 horizontal and 2700 vertical (ISO 178); 3DXTech quotes 2510[5][2][1] | 2798 at 300 mm/s, 2868 at classic speed (printed XY, ISO 178)[3] |
| Charpy impact, notchedkJ/m² | 3.4 ± 0.9 printed horizontal and 3.6 ± 0.4 printed vertical, ISO 179-1 notched (Prusament)[2] | 5.0 at 300 mm/s, 6.1 at classic speed (printed XY, ISO 179, notched)[3] |
| Other impact data | Izod notched 26.6-36.3 J/m XZ against 21.7-27.2 J/m ZX; unnotched 260-406 J/m XZ against 68-116 J/m ZX (printed, ASTM D256/D4812, Stratasys). Charpy unnotched 19.7 +/- 4.3 horizontal and 39 +/- 10 vertical (Prusament, ISO 179-1)[5][2] | Printing at 300 mm/s instead of 46.7 mm/s costs 4.6 % tensile strength and 18 % notched Charpy[3] |
| Layer adhesion / Z tensileMPa | 28-37 at break (printed ZX, ASTM D638, Stratasys F900 and F3300) against 72 +/- 5 at yield printed vertical (ISO 527-1, Prusament on the Pro HT90 with a 0.6 mm nozzle and 90 °C chamber) — a fourfold spread driven by chamber temperature and bead size[5][2] | 32.4 at 300 mm/s, 37.3 at classic speed (printed Z, ISO 527); 35.3 for Creality Hyper PLA vs 23.0 for average PLA on identical bars[3][30] |
| Brittleness1–5 | Brittle — snaps with little warning; notched Charpy only 3.4 kJ/m²[2] | Moderate[3] |
| Hardness (scale-specific)Shore A / Shore D / Rockwell | Shore D 83.5 (Prusa Polymers method); Rockwell M110 / R126 on extruded PEI stock (ASTM D785)[2][31] | 78.7 Shore D measured on printed bars for Sunlu PLA Meta (My Tech Fun), against 75.3 for the same maker's plain PLA[32] |
| Creep resistance / sustained load1–5 | Excellent — holds load for years. Printed coupons hold 215 °C heat deflection at 1.8 MPa (ASTM D648) and extruded PEI stock is rated 170 °C long-term service[5][31] | Poor — 12 mm bar sagged to 17.7 mm over 6 days at 1.25 kg[30] |
| Fatigue / repeated-flex resistance1–5 | Not documented | Poor — no grade-specific S-N curve; plain printed PLA ran 38 000–49 000 cycles at 30 % of tensile strength (R = 0.2)[33][28] |
| Elasticity / flexibility1–5 | Rigid[2] | Rigid[3] |
| Z strength as % of XY% | 36-40 (Stratasys ZX against XZ tensile at break, ASTM D638) against 76 (Prusament vertical against horizontal tensile yield, ISO 527-1)[5][2] | 74 at 300 mm/s, 81 at classic speed (printed)[3] |
| Thermal Properties | ||
| HDT at 0.45 MPa°C | 207 (Prusament, ISO 75 at 0.45 MPa) to 217 (printed XY 216.9 and XZ 217.1, ASTM D648 Method B at 66 psi, Stratasys); 3DXTech quotes 208[2][5][1] | 53 (ISO 75, 0.45 MPa)[3] |
| HDT at 1.8 MPa°C | 194 (Prusament, ISO 75 at 1.8 MPa) to 215 (printed XY 215.1 and XZ 214.5, ASTM D648 Method B at 264 psi, Stratasys) — the highest heat deflection in the dataset[2][5] | 52 (ISO 75, 1.8 MPa)[3] |
| Glass transition (Tg)°C | 209 (moulded plaque, ASTM D7426 inflection point, Stratasys); 217 (DSC, 3DXTech)[5][1] | 59 (DSC)[3] |
| Melting point / Vicat°C | Not documented | 164 peak melt (DSC); crystallisation 96 °C, Vicat 61 °C[3] |
| Continuous service temperature°C | 170 long-term service on extruded PEI stock, converted from 338 °F; 200 short term[31] | 53 — loaded bars begin to move at this temperature[30] |
| Thermal expansion (CTE)µm/m·K | 36.1 (printed XY, -50 to 60 °C, ASTM E831), falling to 29.8 over 60-205 °C; ZX gives 32.5 over -50 to 110 °C and 16.2 over 110-165 °C[5] | 96–99 for plain printed PLA (fibre Bragg grating, 25–50 °C); no grade-specific measurement published[34] |
| Flammability / UL 94 | UL 94 V-0 at 1.5 mm, rated on the base resin[1] | Flammable; no UL 94 rating published by the major brands[21][4] |
| Environment & Chemical | ||
| UV resistance1–5 | Not documented | Degrades within weeks outdoors[28][35] |
| Chemical resistance | Not documented | Good against weak acids, oils and grease; poor against strong acids and alkalis[3] |
| Water / humidity resistance in service1–5 | Not documented | Good — insoluble in water[21] |
| Food contact | Not documented | Base resin is food-contact grade, but printed layer grooves harbour bacteria; Prusa advises against food use[28] |
| Biodegradability / compostability | Not documented | Industrially compostable only — needs sustained 55 °C; not home compostable[36][28] |
| Recyclability | Not documented | Mechanically recyclable; not accepted in household plastic collection[36] |
| Health & Safety | ||
| Fume toxicity1–5 | Moderate — measurable VOCs and UFPs, ventilation advised. None of these polymers was in the chamber study, and all are processed far above the temperatures it covered[37] | Low hazard — minimal VOC and particle emission[37] |
| Ventilation / filtration requirement1–5 | Ventilated room or enclosure recommended[37] | None needed in a normal room[37] |
| Post-Processing | ||
| Sanding & machining | Not documented | Wet sanding — dry sanding heats the surface by friction and smears it[35][28] |
| Gluing & solvent welding | Not documented | Cyanoacrylate for most joints; some grades partially dissolve and bond with acetone[28][38] |
| Vapour / chemical smoothing | Not documented | No practical vapour smoothing — only chloroform, hot benzene or THF, which are laboratory-only[28] |
| Support material pairing | Not documented | PolySupport and PolyDissolve S1 (Polymaker)[3] |
| Solvents & Solubility | ||
| Soluble in | Chlorinated hydrocarbons — dichloromethane and chloroform — are solvents for polyetherimide. Laboratory reagents.[39][40] | Chloroform: 10 % w/v in 2–4 h at 23 °C, every grade and morphology; THF and DMF only at 65 °C. Laboratory reagents.[41] |
| Softened or crazed by | Acetone, MEK, benzene, toluene and butyl acetate craze or stress-crack it; alcohols, fuels and dilute acids do not.[40][39] | Acetone, ethyl acetate and toluene plasticise it but dissolve <1 % even at 65 °C; submersion in acetone crazes and destroys parts.[41][42] |
| Solvent welding & smoothing agent | Dichloromethane is the only welding route, and it is a controlled carcinogen rather than a workshop material.[39][40] | Chloroform vapour smooths and welds PLA at the cost of tensile strength; acetone does not smooth it at all.[43][42] |
Material entries describe families or representative grades, not an interchangeable specification for every spool. Test methods, orientations and conditions may differ. Unknown values are marked “Not documented”. Prices and source dates remain historical snapshots; check the linked guide for product details. Differences highlight text, not a universal winner.
Sources for this comparison
- ThermaX PEI 1010 Technical Data Sheet v4 3DXTech · 2026-08 · tds
- Prusament PEI 1010 Technical Datasheet v1.0 Prusa Polymers · 2024-09 · tds
- PolySonic PLA Technical Data Sheet V5.4 Polymaker · 2024-11 · tds
- PolyLite PLA Technical Data Sheet V5.4 Polymaker · 2024-11 · tds
- ULTEM 1010 Resin — FDM Material Data Sheet Stratasys · 2026-06 · tds
- 3DXTech product catalogue 3DXTech · 2026-08 · vendor
- Kimya PEI-1010 Amber Yellow 1.75 mm 500 g igo3d · 2026-08 · vendor
- Prusa Prusament PEI 1010 Natural (NFC), 1.75 mm / 500 g 3DJAKE · 2026-08 · vendor
- 3D4Makers product catalogue 3D4Makers · 2026-08 · vendor
- IEMAI 3D PEI 1010 3D Printing Filament — store page IEMAI 3D · 2026-08 · vendor
- PolySonic PLA 1.75mm/1kg — product page Polymaker Shop · 2026-08 · vendor
- Overture High Speed PLA 1.75mm Overture3D · 2026-08 · vendor
- High Speed PLA filament collection Anycubic Official Store · 2026-08 · vendor
- PLA Meta filament collection Sunlu Official Store · 2026-08 · vendor
- QIDI PLA Rapido 1.75mm 1kg 3D Printers Depot · 2026-08 · vendor
- Prusament PLA Prusa Pro Green 1kg (NFC) Prusa Research · 2026-08 · vendor
- PolySonic PLA — product page Polymaker · 2026-08 · vendor
- Creality PLA filament collection Creality Official Store · 2026-08 · vendor
- Polymaker Launches New High-Speed 3D Printing Filament — PolySonic PLA & PLA Pro Polymaker · 2023-11 · doc
- PLA Basic — product page Bambu Lab US Store · 2026-08 · vendor
- Bambu Filament Technical Data Sheet V3.0 — PLA Basic Bambu Lab · 2026-08 · tds
- Max volumetric speed Prusa Knowledge Base · 2026-08 · doc
- PLA — Ultimate 3D Printing Materials Guide Simplify3D · 2026-08 · doc
- Prusament PEI 1010 — material page Prusa Polymers · 2026-08 · doc
- Filament Material Guide Prusa Knowledge Base · 2026-08 · doc
- Prusament PLA — material page Prusa Polymers · 2026-08 · doc
- THERMAX PEI 1010 — product page (print recommendations) 3DXTech · 2026-08 · doc
- PLA — material guide Prusa Knowledge Base · 2026-08 · doc
- Wet Filament — signs, causes and drying Polymaker Wiki · 2026-08 · doc
- Creality Hyper PLA filament review — results spreadsheet My Tech Fun (Igor Gaspar) · 2026-08 · test
- TECAPEI natural (PEI) — stock shape properties Ensinger · 2026-08 · tds
- Carbon Fiber PLA vs META-PLA vs PLA+ vs PLA by Sunlu — results spreadsheet My Tech Fun (Igor Gaspar) · 2026-08 · test
- Mechanical Properties of Additively Manufactured Polymeric Materials — PLA and PETG — For Biomechanical Applications Polymers 16(13):1868 · 2024-06 · paper
- Characterization of Thermal Expansion Coefficient of 3D Printing Polymeric Materials Using Fiber Bragg Grating Sensors Materials 17(18):4668 · 2024-09 · paper
- Prusament PLA Technical Data Sheet v1.0 Prusa Polymers · 2018-09 · tds
- Filamentive PLA (recycled) — product page Filamentive · 2026-08 · vendor
- Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments (Azimi et al.) Environmental Science & Technology 50(3) 1260-1268 · 2016-01 · paper
- Prusament rPLA Corn Pigment 1kg — product page Prusa Research · 2026-08 · vendor
- Radel PPSU, Veradel PESU, Acudel modified PPSU Design Guide — environmental stress cracking tables Solvay Specialty Polymers · 2026-08 · tds
- Chemical resistance — resistance of Ensinger plastics to chemicals (DIN 50 014, 23/50) Ensinger · 2026-08 · tds
- Solubility Study of Ingeo Biopolymer Grades in Common Organic Solvents (NWPD003) NatureWorks · 2019-10 · tds
- Improve your 3D prints with chemical smoothing Prusa Research · 2026-08 · doc
- Effect of vapour smoothing in trichloromethane on 3D printed PLA — surface, mechanical and chemical structure Pitale, Keche & Chopra, Engineering Research Express 6(4) 045579 · 2024-12 · paper