Filament comparison
PC-FR vs PLA Glow
Compare printing settings, strength, heat resistance, dated prices and sources.
2 selected · all documented properties
| Property | Flame-retardant PC (PC-FR)PC | Glow-in-the-dark PLAPLA |
|---|---|---|
| Market snapshot | ||
| Listing priceUSD/kg; dated snapshots | $87.50/kg median; $54.99–$224.00/kg across 4 dated product listings | $24.99/kg median; $19.99–$49.16/kg across 5 dated product listings |
| Identity & Market | ||
| Base polymer / chemistry | Flame-retardant polycarbonate. Polymaker builds its grade on Covestro's Makrolon family and rates it UL 94 V-0[1][2] | PLA with a phosphorescent additive at 2–20 wt% (Bambu Lab SDS, filler not named)[3] |
| Densityg/cm³ | 1.18 (Bambu Lab) and 1.2 (Polymaker), ISO 1183[2][1] | 1.24 (colorFabb) to 1.26 (Bambu Lab), ISO 1183[4][5] |
| Typical priceUSD/kg | 1 kg-equivalent spools span 55–224; the two mainstream 1 kg grades are 55 and the industrial grades 120–224[2][6] | 1 kg spools cluster near 25[7][8] |
| Price range across brandsUSD/kg | 55–224 across brands; Bambu Lab and Polymaker 55, 3DXTech FR PC/ABS 120, 3DXLABS FR-PC 224[2][6][9] | 20–49 across brands; ELEGOO 20, Bambu Lab 25, Polymaker 25, Filament PM 49 on 0.5 kg spools[10][7][8][11] |
| Market availability1–5 | Available from several mainstream brands[2][6][9] | Stocked by most mainstream brands[7][8][10] |
| Spool sizes & diameters | 1.75 mm; 0.75 and 1 kg spools[6][9][2] | 1.75 and 2.85 mm; 0.75 and 1 kg spools[6][5] |
| Typical applications | Electrical enclosures, transport interiors and battery housings that must meet a flammability rating[1][2] | Signage, novelty and cosplay parts that glow after light exposure[4] |
| Diameter tolerance± mm | ±0.03 (Bambu Lab PC FR)[2] | Not documented |
| Printing Parameters | ||
| Nozzle temperature°C | 260–280 (Bambu Lab); 250–270 (Polymaker)[2][1] | 190–230 on the Bambu Lab TDS against 210–240 in its own material table; colorFabb advises 195–220[4][12][5] |
| Bed temperature°C | 90–110 (Bambu Lab); 90–105 (Polymaker)[2][1] | 35–45 (Bambu Lab); 50–60 (colorFabb)[4][5] |
| Enclosure / chamber requirement1–5 | Enclosure required (passive) — Bambu Lab specifies a 45–60 °C chamber, Polymaker 70–100 °C[2][1] | Open frame is fine[4] |
| Recommended chamber temperature°C | 45–60 (Bambu Lab); 70–100 (Polymaker)[2][1] | Not documented |
| Part cooling fan | 0–60 % (Bambu Lab)[2] | Fan on; colorFabb allows 0–100 %[4][5] |
| Bed surface & adhesion aid | Smooth or textured PEI plate (Bambu Lab)[2] | Not documented |
| Maximum volumetric flow (mm³/s; see test conditions)mm³/s | 24 at Bambu Lab's 300 mm/s cap on a 0.4 mm nozzle at 0.2 mm layer[2][13] | Not documented |
| Warping tendency1–5 | Severe — heated chamber needed[1][14] | Not documented |
| Bed-adhesion difficulty1–5 | Needs a specific surface plus adhesive[15][16] | Not documented |
| Stringing / oozing tendency1–5 | Moderate — retraction tuning needed; Polymaker flags stringing as a common PC problem[16] | Not documented |
| Overall printing difficulty1–5 | Advanced — enclosure, hardware upgrades, tuning[2][14] | Easy — minor profile tuning; a hardened nozzle is mandatory[12][8] |
| Extruder requirement | Not documented | Bambu Lab: hardened steel and high-flow nozzles only, 0.2 mm excluded, AMS lite not compatible[12] |
| Hardware Wear & Reliability | ||
| Nozzle hardness required1–4 | Brass fine indefinitely[14] | Hardened steel required[12][8][5] |
| Abrasiveness1–5 | Non-abrasive[1] | Highly abrasive — the phosphor is a hard ceramic; Bambu Lab groups glow with carbon fibre as the materials that wear nozzles and grind AMS PTFE, and both Bambu Lab and Polymaker require a hardened nozzle[12][5] |
| Nozzle clog risk1–5 | Moderate — needs dry filament and a clean nozzle; 3DXTech lists no special nozzle concerns but a 6 h pre-dry at 80 °C[17] | Moderate — needs dry filament and a clean nozzle[12] |
| Heat-creep / jam sensitivity1–5 | Slightly sensitive[15] | Not documented |
| Hotend requirement | All-metal hot end required (Simplify3D)[15] | Hardened steel nozzle; Bambu Lab lists glow-in-the-dark among the filaments its hardened-steel nozzle exists for[18][12] |
| Other hardware wear | Not documented | Bambu Lab reports the filament adds enough feeding resistance to fail prints on the AMS lite; colorFabb warns of brass nozzle wear[12][5] |
| Moisture Behaviour | ||
| Moisture absorption (hygroscopicity)1–5 | Low (0.1–0.3 %) — 0.12 % saturated at 25 °C / 55 % RH (Bambu Lab), half that of unfilled Bambu Lab PC[2][19] | Moderate — 0.46 % saturated at 25 °C / 55 % RH[4] |
| Equilibrium moisture content at ~50 % RH% | 0.12 saturated at 25 °C / 55 % RH (Bambu Lab)[2] | 0.46 saturated at 25 °C / 55 % RH (Bambu Lab)[4] |
| Drying temperature & time | 75 °C for 6 h (Polymaker)[1] | Not documented |
| Symptoms when wet | Bubbling and popping at the nozzle, stringing and a rough surface[20] | Not documented |
| Effect of moisture on strength | No dry-versus-conditioned figures are published. Polymaker calls PC highly hygroscopic and requires a 70–80 °C dry for 6–8 h; run wet, the loss shows as surface defects and poor layer adhesion[16][20] | Polymaker rates PLA low-sensitivity and publishes no dry-versus-conditioned figures for this grade; absorbed water flashes to steam and shows as bubbling and poor layer adhesion[20] |
| Storage requirement | Airtight containers with desiccant to prevent reabsorption[16] | Not documented |
| Mechanical Properties | ||
| Tensile strength (XY)MPa | 60 ± 4 (Bambu Lab) and 67 ± 4.5 (Polymaker) printed XY, ISO 527[2][1] | 32 ± 3 printed XY, ISO 527 (Bambu Lab); colorFabb quotes 61.5 by ISO 527 on its own specimens[4][5] |
| Young's modulusMPa | 1670 ± 40 (Bambu Lab) and 2634 ± 182 (Polymaker) printed XY, ISO 527[2][1] | 2030 ± 210 printed XY, ISO 527 (Bambu Lab); colorFabb 2960[4][5] |
| Elongation at break% | 2.4 ± 0.3 (Bambu Lab) and 3.49 ± 0.7 (Polymaker) at break, printed XY, ISO 527 — the retardant roughly halves unfilled PC's elongation[2][1][21] | 8.6 ± 1.2 printed XY, ISO 527 (Bambu Lab); colorFabb 10.5 at break[4][5] |
| Flexural strengthMPa | 96.6 ± 1.3 printed XY, ISO 178 (Polymaker)[1] | 76 ± 4 printed XY, ISO 178 (Bambu Lab)[4] |
| Flexural modulusMPa | 2518 ± 53 printed XY, ISO 178 (Polymaker)[1] | 2640 ± 130 printed XY, ISO 178 (Bambu Lab); colorFabb 3295[4][5] |
| Charpy impact, notchedkJ/m² | 11.7 ± 1.6 printed XY, ISO 179, notched (Polymaker)[1] | 2.8 (colorFabb, ISO 179-1/1eA) and 8.8 ± 1.7 (Bambu Lab, ISO 179) printed XY, notched[4][5] |
| Other impact data | Notched Charpy 7.5 ± 1.6 kJ/m² at −30 °C printed XY (Polymaker, ISO 179-1/1eA)[1] | Charpy unnotched 27.3 (Bambu Lab) and 30.8 (colorFabb), printed, ISO 179[4][5] |
| Layer adhesion / Z tensileMPa | 21 ± 3 (Bambu Lab) and 46 ± 4.8 (Polymaker) printed Z, ISO 527[2][1] | 26 ± 3 printed Z, ISO 527 (Bambu Lab)[4] |
| Brittleness1–5 | Moderate[2][1] | Brittle — snaps with little warning[4] |
| Hardness (scale-specific)Shore A / Shore D / Rockwell | Rockwell 70 (118) — the source does not name the scales and Shore D 79 on extruded unfilled PC stock (ASTM D785, D2240); no figure is published for a flame-retardant filament[22] | Not documented |
| Creep resistance / sustained load1–5 | Good. Moulded unfilled PC sustained 41 MPa tensile creep at room temperature without breaking, but the retardant package drops the glass transition to 115 °C in Polymaker's grade, so the unfilled rating is not carried over in full[23][1] | Poor — no glow-grade creep test; plain printed PLA sagged from 12 to 16.2–21.8 mm over 5 days at 1.25 kg[24][25][26] |
| Fatigue / repeated-flex resistance1–5 | Not documented | Poor — no grade-specific S-N curve; plain printed PLA ran 38 000–49 000 cycles at 30 % of tensile strength and the glow filler leaves a brittle, highly abrasive compound[27][4] |
| Elasticity / flexibility1–5 | Rigid[1] | Rigid[4] |
| Z strength as % of XY% | 35 (Bambu Lab) to 69 (Polymaker), printed[2][1] | 81 by tensile, 72 by flexural (printed, Bambu Lab)[4] |
| Thermal Properties | ||
| HDT at 0.45 MPa°C | 110 (Polymaker) and 113 (Bambu Lab), ISO 75 at 0.45 MPa[1][2] | 55 (ISO 75, 0.45 MPa)[4] |
| HDT at 1.8 MPa°C | 107 (Polymaker) and 108 (Bambu Lab), ISO 75 at 1.8 MPa[1][2] | 52 (ISO 75, 1.8 MPa)[4] |
| Glass transition (Tg)°C | 115 (Polymaker) and 145 (Bambu Lab), DSC[1][2] | 55 (DSC)[4] |
| Melting point / Vicat°C | Amorphous — no melting point; Vicat 114 (Bambu Lab, ISO 306)[2] | 155 peak melt (DSC); colorFabb quotes above 155 by ISO 3146-C[4][5] |
| Continuous service temperature°C | 113 — Prusa publishes this as the temperature resistance of Prusament PC Blend[28] | Not documented |
| Thermal expansion (CTE)µm/m·K | 68.4 on extruded unfilled PC stock (ASTM D696; source states 3.8e-5 in/in/°F); no figure is published for a flame-retardant grade[22] | Not documented |
| Flammability / UL 94 | UL 94 V-0 (Polymaker PolyMax PC-FR); 3DXTech rates its FR PC/ABS V-0 at 1.5 mm on the base resin[1][29] | Not documented |
| Environment & Chemical | ||
| UV resistance1–5 | Degrades within weeks outdoors unless stabilised[16] | Degrades within weeks outdoors[30] |
| Chemical resistance | Withstands oils, solvents and fuels; Polymaker rates it good against weak acids[16] | Not documented |
| Food contact | Bisphenol-A polycarbonate is not offered as food-contact filament[16] | Not documented |
| Biodegradability / compostability | Not biodegradable[16] | Not documented |
| Recyclability | Mechanically recyclable but not accepted in household plastic collection[16] | Not documented |
| Health & Safety | ||
| Fume toxicity1–5 | Moderate — measurable VOCs and UFPs, ventilation advised[31] | Low hazard — minimal VOC and particle emission[31] |
| Ultrafine-particle emission rateparticles/min | ≈4 × 10¹⁰ median — the highest ultrafine-particle rate of the nine filaments in the chamber study, above every ABS tested[31] | Not documented |
| Ventilation / filtration requirement1–5 | Ventilated room or enclosure recommended[31][14] | None needed in a normal room[31] |
| Post-Processing | ||
| Sanding & machining | Sands and machines well; the toughness means it cuts rather than chips[15] | Not documented |
| Gluing & solvent welding | Cyanoacrylate; dichloromethane solvent-welds PC but is a laboratory reagent[15] | Not documented |
| Vapour / chemical smoothing | No practical vapour smoothing[15] | Not documented |
| Support material pairing | Prints its own supports; 3DXTech sells a dedicated PC break-away support[15] | Support for PLA (Bambu Lab)[4] |
| Dimensional accuracy & detail | Not documented | Glow brightness rises with wall thickness; 0.2 mm nozzles are not usable[12] |
| Solvents & Solubility | ||
| Soluble in | Dichloromethane, chloroform, DMF and dioxane dissolve it outright (Covestro, 6 days at 23 °C). Laboratory reagents.[32] | Chloroform dissolves the PLA matrix (10 % w/v, 2–4 h at 23 °C) and leaves the filler as loose sludge; laboratory reagent.[33] |
| Softened or crazed by | Methanol, butyl acetate, ether, 1 % NaOH and phthalate plasticisers stress-crack it; acetone, MEK and xylene swell it.[32] | Acetone, ethyl acetate and toluene plasticise the matrix but dissolve <1 % even at 65 °C; acetone submersion crazes parts.[33][34] |
| Solvent welding & smoothing agent | Dichloromethane cement welds PC — 16.5 MPa lap shear at one week (IPS Weld-On 3). A controlled carcinogen.[35] | Chloroform vapour attacks only the resin fraction, so the filler is left standing proud; no workshop-safe agent exists.[36][34] |
Material entries describe families or representative grades, not an interchangeable specification for every spool. Test methods, orientations and conditions may differ. Unknown values are marked “Not documented”. Prices and source dates remain historical snapshots; check the linked guide for product details. Differences highlight text, not a universal winner.
Sources for this comparison
- PolyMax PC-FR Technical Data Sheet V5.5 Polymaker · 2024-11 · tds
- Bambu Filament Technical Data Sheet V1.0 — PC FR Bambu Lab · 2026-08 · tds
- Safety Data Sheet SDS20251127A12 — Bambu PLA Glow Bambu Lab · 2025-11 · msds
- Bambu Filament Technical Data Sheet — PLA Glow Bambu Lab · 2026-08 · tds
- glowFill technical data sheet colorFabb · 2026-08 · tds
- Polymaker product catalogue Polymaker · 2026-08 · vendor
- PLA Glow — product page Bambu Lab US Store · 2026-08 · vendor
- Panchroma Luminous PLA — product page Polymaker Shop · 2026-08 · vendor
- 3DXTech product catalogue 3DXTech · 2026-08 · vendor
- ELEGOO product catalogue ELEGOO · 2026-08 · vendor
- Filament PM PLA GlowJet technical data sheet Filament PM (Plasty Mladec) · 2026-08 · tds
- PLA Usage Guide Bambu Lab Wiki · 2026-08 · doc
- Max volumetric speed Prusa Knowledge Base · 2026-08 · doc
- ABS / ASA / PC Usage Guide Bambu Lab Wiki · 2026-08 · doc
- Polycarbonate — Ultimate 3D Printing Materials Guide Simplify3D · 2026-08 · doc
- PC — material basics Polymaker Wiki · 2026-08 · doc
- 3DXTech Firewire FR-PC/ABS product page 3DXTech · 2026-08 · vendor
- Nozzles — material and compatibility Bambu Lab Wiki · 2026-08 · doc
- Bambu Filament Technical Data Sheet V2.0 — PC Bambu Lab · 2026-08 · tds
- Wet Filament — signs, causes and drying Polymaker Wiki · 2026-08 · doc
- PolyLite PC Technical Data Sheet V5.4 Polymaker · 2024-11 · tds
- TECANAT natural (PC) — stock shape properties Ensinger · 2026-08 · tds
- Experimental data for creep and dynamic mechanical properties of polycarbonate and polycarbonate/ABS Data in Brief 42:108264 · 2022-06 · paper
- BambuLab PLA Basic vs PLA Tough vs PLA-CF — results spreadsheet My Tech Fun (Igor Gaspar) · 2026-08 · test
- Polymaker PLA Pro vs PLA-CF — results spreadsheet My Tech Fun (Igor Gaspar) · 2026-08 · test
- Carbon Fiber PLA vs META-PLA vs PLA+ vs PLA by Sunlu — results spreadsheet My Tech Fun (Igor Gaspar) · 2026-08 · test
- Mechanical Properties of Additively Manufactured Polymeric Materials — PLA and PETG — For Biomechanical Applications Polymers 16(13):1868 · 2024-06 · paper
- Prusament PC Blend Technical Datasheet v1.1 Prusa Polymers · 2022-02 · tds
- Firewire Flame Retardant PC/ABS Technical Data Sheet Rev 3.0 3DXTech · 2026-08 · tds
- PLA — material guide Prusa Knowledge Base · 2026-08 · doc
- Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments (Azimi et al.) Environmental Science & Technology 50(3) 1260-1268 · 2016-01 · paper
- Makrolon — The chemical resistance (Makrolon 2800, 6 days at 23 °C and 50 °C) Covestro · 2016-12 · tds
- Solubility Study of Ingeo Biopolymer Grades in Common Organic Solvents (NWPD003) NatureWorks · 2019-10 · tds
- Improve your 3D prints with chemical smoothing Prusa Research · 2026-08 · doc
- Weld-On 3 Acrylic Plastic Cement — technical data sheet (shipped as dichloromethane) IPS Corporation · 2002-07 · tds
- Effect of vapour smoothing in trichloromethane on 3D printed PLA — surface, mechanical and chemical structure Pitale, Keche & Chopra, Engineering Research Express 6(4) 045579 · 2024-12 · paper