| Property | Glass-fibre PA6 (PA6-GF)PA | PEEKHIGHTEMP |
|---|---|---|
| Market snapshot | ||
| Listing priceUSD/kg; dated snapshots | $59.98/kg median; $39.99–$130.00/kg across 6 dated product listings | $531.87/kg median; $296.14–$770.00/kg across 5 dated product listings |
| Identity & Market | ||
| Base polymer / chemistry | PA6 reinforced with chopped glass fibre — Polymaker's grade is 25 wt%[1][2] | Polyether ether ketone — a semi-crystalline polyaryletherketone[3] |
| Densityg/cm³ | 1.14 (Bambu Lab) and 1.20 (Polymaker Fiberon), ISO 1183[2][1] | 1.30 (ISO 1183)[3][4] |
| Typical priceUSD/kg | 1 kg-equivalent spools span 40–130; the middle of the market is about 60[2][5][6] | 1 kg-equivalent spools span 296–770; the middle of the market is about 532[7][8][9] |
| Price range across brandsUSD/kg | 40–130 across brands; SUNLU 40, YXPOLYER 45, Polymaker Fiberon and Bambu Lab 60, 3DXTech FibreX 87, Obsidian Nylon 6+GF 130[5][2][7][6][10] | 296-770 across brands and spool sizes; 3D4Makers recycled R-PEEK 296 at 750 g, IEMAI 3D 420 at 1 kg, LEHVOSS Luvocom 3F PEEK 9581 532 at 2 kg, 3DXTech ThermaX PEEK 770 at 500 g[7][8][9] |
| Market availability1–5 | Stocked by most mainstream brands[2][5][7][6][10] | Niche, a handful of specialist brands[7][8][4] |
| Spool sizes & diameters | 1.75 and 2.85 mm; 0.5, 0.75 and 1 kg spools[5][7][2] | 1.75 and 2.85 mm; 200 g to 2 kg spools[7][8][4] |
| Typical applications | Stiff, heat-resistant structural parts where a matte finish and lower cost beat carbon fibre[2][1] | Aerospace brackets, semiconductor handling, sterilisable medical tooling and downhole parts[3] |
| Printing Parameters | ||
| Nozzle temperature°C | 260–290 (Bambu Lab)[2] | 380-400 (3DXTech printed-specimen conditions); Victrex quotes a 340-450 melt range for AM 450 FIL[3][4] |
| Bed temperature°C | Not documented | 130–140 (3DXTech)[3] |
| Enclosure / chamber requirement1–5 | Enclosure required (passive) — Bambu Lab specifies a 45–60 °C chamber[2] | Actively heated chamber required[11][12] |
| Recommended chamber temperature°C | 45–60 (Bambu Lab)[2] | Not less than 150 for semi-crystalline printing (Victrex AM 450 FIL); bed above 150[4] |
| Bed surface & adhesion aid | PEI sheet with a glue stick, or a dedicated adhesive such as Magigoo[13][14] | Not documented |
| Maximum volumetric flow (mm³/s; see test conditions)mm³/s | 10 at Bambu Lab's 130 mm/s cap on a 0.4 mm nozzle at 0.2 mm layer[2][15] | Not documented |
| Warping tendency1–5 | Not documented | Severe — heated chamber needed[11] |
| Bed-adhesion difficulty1–5 | Needs a specific surface plus adhesive[13] | Very difficult — special plates or slurry required[11] |
| Stringing / oozing tendency1–5 | Moderate — retraction tuning needed[14] | Not documented |
| Overall printing difficulty1–5 | Expert / industrial hardware only[2][16] | Expert / industrial hardware only[11][12] |
| Extruder requirement | 0.6 mm nozzle recommended by Bambu Lab; 0.4 and 0.8 also supported[2] | An all-metal hot end rated above 400 °C and a heated chamber; 3DXTech tests at 0.25 mm layer height on a 0.4 mm nozzle[3][11] |
| Hardware Wear & Reliability | ||
| Nozzle hardness required1–4 | Hardened steel required — Polymaker measures brass nozzle life at about 9 h on PA6-GF25 and recommends hardened steel or ruby[1] | Brass fine indefinitely for unfilled grades, but brass softens near these nozzle temperatures — hardened or plated hot ends are the norm[11] |
| Abrasiveness1–5 | Highly abrasive — standard GF composite; Polymaker puts brass nozzle life at roughly 9 h on PA6-GF25[1] | Non-abrasive when unfilled[3] |
| Nozzle clog risk1–5 | Very high — frequent jams without careful setup[16] | Moderate — needs dry filament and a clean nozzle; 3DXTech lists no special nozzle concerns but a mandatory 120 °C pre-dry before every print[17] |
| Heat-creep / jam sensitivity1–5 | Moderate — good heatbreak cooling needed[13] | Not documented |
| Hotend requirement | May require an all-metal hot end (Simplify3D)[13] | Not documented |
| Moisture Behaviour | ||
| Moisture absorption (hygroscopicity)1–5 | Very high (>2 %) — 2.56 % saturated at 25 °C / 55 % RH (Bambu Lab) and 3.33 % equilibrium (Polymaker Fiberon), the highest in the dataset[2][1] | Not documented |
| Equilibrium moisture content at ~50 % RH% | 2.56 saturated at 25 °C / 55 % RH (Bambu Lab); 3.33 equilibrium (Polymaker Fiberon PA6-GF25)[2][1] | 0.45 at saturation, 23 °C (ISO 62); 0.55 at 100 °C[4] |
| Drying temperature & time | 80 °C for 8–12 h (Bambu Lab)[2] | 120 °C for 5 h, target below 0.020 % moisture (Victrex AM 450 FIL)[4] |
| Symptoms when wet | Popping and cracking during extrusion, then hard-to-diagnose defects[18] | Not documented |
| Effect of moisture on strength | Polymaker publishes dry and wet printed blocks for PA6-GF25 itself: at 4.57 % moisture tensile falls 80.1 → 40.2 MPa and modulus 5357 → 1794 MPa, while notched Charpy rises 10.0 → 28.0 kJ/m²[1][18] | No dry-versus-conditioned figures are published; 3DXTech mandates a 120 °C, 4 h pre-dry before every print because trapped water flashes to steam at these nozzle temperatures[17] |
| Storage requirement | Sealed below 20 % RH with desiccant[16] | Not documented |
| Hydrolysis at melt temperature | Polymaker specifies an 80–100 °C dry and storage below 20 % RH; no molecular-weight loss figure is published, and the wet data it does publish is conditioning rather than melt hydrolysis[19][20] | Not documented |
| Mechanical Properties | ||
| Tensile strength (XY)MPa | 75 ± 6 (Bambu Lab) and 80.1 ± 1.8 (Polymaker Fiberon, dry/annealed) printed XY, ISO 527; Fiberon falls to 40.2 ± 2.1 conditioned to 4.57 % moisture. Stratasys FDM PA6/66-GF30-FR gives 60.2-61.1 at break and 61.7-62.3 at yield printed XZ (ASTM D638)[2][1][21] | 60-100 (printed XY): Victrex AM 450 FIL 60-80 at yield and 3DXTech 100, both ISO 527; 98 at yield injection-moulded[3][4] |
| Young's modulusMPa | 2850 ± 260 (Bambu Lab) and 5357 ± 211 (Polymaker Fiberon, dry) printed XY, ISO 527; Fiberon falls to 1794 ± 84 conditioned. Stratasys FDM PA6/66-GF30-FR gives 5600-5830 printed XZ against 3050-3140 in ZX (ASTM D638)[2][1][21] | 3000-4000 (printed XY, ISO 527, Victrex AM 450 FIL); 3720 (3DXTech); 4000 injection-moulded[3][4] |
| Elongation at break% | 2.4 ± 0.2 dry (Polymaker Fiberon) to 3.9 ± 0.8 (Bambu Lab) printed XY, ISO 527; the Fiberon grade rises to 4.2 ± 0.7 conditioned[2][1] | 28 (printed XY, ISO 527) — remarkably ductile for a high-temperature polymer[3] |
| Flexural strengthMPa | Not documented | 130 (printed XY, ISO 178)[3] |
| Flexural modulusMPa | 3670 ± 140 printed XY, ISO 178 (Bambu Lab)[2] | 2700 (printed XY, ISO 178)[3] |
| Charpy impact, notchedkJ/m² | 10.0 ± 0.7 printed XY dry and 28.0 ± 1.0 conditioned, ISO 179 notched (Polymaker Fiberon); Bambu Lab 7.2 ± 2.3[1][2] | 6.0 (injection-moulded, ISO 179/1eA); unnotched does not break[4] |
| Other impact data | Charpy unnotched 27.2 ± 2.2 printed XY (Bambu Lab, ISO 179). Stratasys FDM PA6/66-GF30-FR gives Izod notched 74.6-77.1 J/m printed XZ against 17.2-22.1 in ZX (ASTM D256)[2][21] | Izod notched 7.0 kJ/m2 injection-moulded (ISO 180/A). Printed anisotropy is extreme: VICTREX AM 200 on a Stratasys F900 gives Izod notched 1380-1530 J/m XZ against 30-62 J/m ZX (ASTM D256)[4][22] |
| Layer adhesion / Z tensileMPa | 27 ± 5 (Bambu Lab) and 60.7 ± 1.1 (Polymaker Fiberon, dry) printed Z, ISO 527 — the two makers differ by more than a factor of two; Fiberon falls to 26.3 ± 1.5 conditioned. Stratasys FDM PA6/66-GF30-FR gives 23.7-24.4 at break printed ZX (ASTM D638)[2][1][21] | 20-85 at yield (printed ZX, ISO 527, Victrex AM 450 FIL); the spread is set by chamber temperature and weld quality[4] |
| Brittleness1–5 | Brittle — snaps with little warning; elongation at break 2.4 % in XY[1] | Tough — absorbs impact, yields before breaking[3] |
| Hardness (scale-specific)Shore A / Shore D / Rockwell | Rockwell M88 / R117 on extruded PA66-GF30 stock (ASTM D785)[23] | Shore D 84.5 (injection-moulded, ISO 868); Rockwell M100 / R125 on extruded PEEK stock (ASTM D785)[4][24] |
| Creep resistance / sustained load1–5 | Good. Ensinger lists high creep resistance as a headline property of extruded PA66-GF30 stock; the rating is held below Excellent because equilibrium moisture uptake of 3.33 % softens the matrix in service[23][1] | Excellent — holds load for years. Victrex rates PEEK for long-term creep; injection-moulded flexural stress at 3.5 % strain falls only from 125 MPa at 23 °C to 85 MPa at 125 °C, and extruded stock is rated to 249 °C continuous[25][4][24] |
| Fatigue / repeated-flex resistance1–5 | Good. Ensinger lists high fatigue strength as a headline property of extruded PA66-GF30 stock[23] | Excellent — living hinges viable. Victrex rates PEEK for long-term fatigue as well as creep[25] |
| Elasticity / flexibility1–5 | Rigid[2] | Rigid[3] |
| Z strength as % of XY% | 36 (Bambu Lab) to 76 (Polymaker Fiberon), printed; Stratasys FDM PA6/66-GF30-FR gives 39-41 (ZX against XZ tensile at break, ASTM D638)[2][1][21] | 71-84 (VICTREX AM 200 LMPAEK printed on the Stratasys F900 and Fortus 450mc, ZX against XZ tensile yield, ASTM D638); unfilled PEEK's own ZX spread is wider[22] |
| Thermal Properties | ||
| HDT at 0.45 MPa°C | 182 (Bambu Lab) and 191 (Polymaker Fiberon), ISO 75 at 0.45 MPa. Stratasys FDM PA6/66-GF30-FR gives 161 printed XY and 185 XZ (ASTM D648 at 66 psi)[2][1][21] | 140 (printed XY, ISO 75 at 0.45 MPa, 3DXTech)[3] |
| HDT at 1.8 MPa°C | 157 (Polymaker Fiberon) and 158 (Bambu Lab), ISO 75 at 1.8 MPa[2][1] | 152 (unannealed, ISO 75-2/Af, Victrex AM 450 FIL); 160 on extruded stock (ASTM D648 at 264 psi)[4][24] |
| Glass transition (Tg)°C | 67 (Bambu Lab) and 70.4 (Polymaker Fiberon), DSC; Stratasys measures 51.5 on FDM PA6/66-GF30-FR (ASTM D7426)[2][1][21] | 143 (DSC, 3DXTech); Victrex gives onset 143 and midpoint 150 (ISO 11357-2)[3][4] |
| Melting point / Vicat°C | 214.5 (Polymaker Fiberon) and 219 (Bambu Lab) melting, DSC; Vicat 210–212 (ISO 306)[2][1] | 343 melting (ISO 11357-3, Victrex); VICTREX AM 200 LMPAEK melts at 303[4][22] |
| Continuous service temperature°C | Not documented | 240 UL 746B relative thermal index, strength (RTI electrical 260, impact 180); Ensinger rates extruded PEEK stock at 249 long term[4][24] |
| Thermal expansion (CTE)µm/m·K | 48.6 on extruded PA66-GF30 stock (ASTM D696; source states 2.7e-5 in/in/°F). Stratasys measures much higher on printed FDM PA6/66-GF30-FR — 95.4 over -20 to 5 °C and 214 over 25 to 80 °C in XY (ASTM E831)[23][21] | 37.8 (extruded PEEK stock, 23-60 °C, ASTM E831; source states 2.1e-5 in/in/°F), rising to 41.9 at 60-100 °C and 55.8 at 100-150 °C[24] |
| Flammability / UL 94 | Flammable; no UL 94 rating published for the grades surveyed[19] | UL 94 V-0 at 1.5 mm on the base resin; glow-wire flammability index 960 °C at 2.0 mm (IEC 60695-2-12)[3][4] |
| Environment & Chemical | ||
| UV resistance1–5 | Months outdoors before embrittlement — unstabilised polyamide yellows under UV[14] | Not documented |
| Chemical resistance | Withstands oils, fuels and alkalis[14] | Outstanding — resistant to almost all solvents and to steam sterilisation[3] |
| Water / humidity resistance in service1–5 | Absorbs water, properties shift[18] | Excellent — essentially unaffected; 0.45 % water at saturation and resistant to steam sterilisation[4][3] |
| Food contact | Not food-contact certified as filament[14] | Not documented |
| Biodegradability / compostability | Not biodegradable[14] | Not documented |
| Recyclability | Not accepted in household plastic collection[14] | Not documented |
| Electrical & ESD properties | Surface resistivity above 10¹² ohm — insulating (Polymaker Fiberon, ANSI/ESD S11.11)[1] | Not documented |
| Health & Safety | ||
| Fume toxicity1–5 | Moderate — measurable VOCs and UFPs, ventilation advised[26] | Moderate — measurable VOCs and UFPs, ventilation advised. None of these polymers was in the chamber study, and all are processed far above the temperatures it covered[26] |
| VOC emission rateµg/min | Up to 180 caprolactam, the dominant VOC from nylon and the largest single-VOC rate in the study[26] | Not documented |
| Ultrafine-particle emission rateparticles/min | ≈2 × 10⁸ median for nylon — low for particles despite the highest VOC mass measured[26] | Not documented |
| Hazardous species emitted | Caprolactam, at up to 180 µg/min from nylon filament[26] | Not documented |
| Ventilation / filtration requirement1–5 | Ventilated room or enclosure recommended[26] | Ventilated room or enclosure recommended[26] |
| Dust & fibre handling hazard | Glass fibre is bound in the matrix; avoid inhaling sanding dust[1] | Not documented |
| Post-Processing | ||
| Sanding & machining | Sands poorly — gums rather than powders[13] | Not documented |
| Gluing & solvent welding | Cyanoacrylate; no common solvent welds polyamide[13] | Not documented |
| Vapour / chemical smoothing | No practical vapour smoothing[13] | Not documented |
| Solvents & Solubility | ||
| Soluble in | Formic acid, phenol, m-cresol and hexafluoroisopropanol dissolve the matrix at 23 °C, leaving the fibre; laboratory reagents.[27] | 95–98 wt% sulphuric acid dissolves it — 10 g per 100 mL at 40–70 °C gives a dark red solution. Laboratory route only.[28][29] |
| Softened or crazed by | Zinc chloride solutions stress-crack the nylon matrix, alcoholic calcium chloride dissolves it, mineral acids attack it.[27] | Concentrated nitric, hydrofluoric, hydrobromic and hydriodic acids attack it; DCM, DMSO and THF swell thin-walled sections.[30][29] |
| Solvent welding & smoothing agent | None — nylon's only solvents (formic acid, phenol, HFIP) degrade the part, and the fibre blocks surface flow anyway.[27] | None — no solvent softens PEEK, so parts are joined thermally or mechanically, never chemically.[30][29] |
Material entries describe families or representative grades, not an interchangeable specification for every spool. Test methods, orientations and conditions may differ. Unknown values are marked “Not documented”. Prices and source dates remain historical snapshots; check the linked guide for product details. Differences highlight text, not a universal winner.
Sources for this comparison
- Fiberon PA6-GF25 Technical Data Sheet V1.1 Polymaker · 2024-12 · tds
- Bambu Filament Technical Data Sheet — PA6-GF Bambu Lab · 2026-08 · tds
- ThermaX PEEK Technical Data Sheet v3 3DXTech · 2026-08 · tds
- VICTREX AM 450 FIL — datasheet Victrex · 2025-12 · tds
- Polymaker product catalogue Polymaker · 2026-08 · vendor
- SUNLU Nylon-6 Glass Fiber (PA6-GF) 3D Printer Filament 1 kg — product page SUNLU · 2026-08 · vendor
- 3DXTech product catalogue 3DXTech · 2026-08 · vendor
- 3D4Makers product catalogue 3D4Makers · 2026-08 · vendor
- IEMAI 3D PEEK 3D Printing Filament — store page IEMAI 3D · 2026-08 · vendor
- YXPOLYER PA6-GF Black 1 kg — product page YXPOLYER · 2026-08 · vendor
- Prusament PEI 1010 Technical Datasheet v1.0 Prusa Polymers · 2024-09 · tds
- Prusament PEI 1010 — material page Prusa Polymers · 2026-08 · doc
- Nylon — Ultimate 3D Printing Materials Guide Simplify3D · 2026-08 · doc
- PA (Nylon) — material basics Polymaker Wiki · 2026-08 · doc
- Max volumetric speed Prusa Knowledge Base · 2026-08 · doc
- Wet Filament — signs, causes and drying Polymaker Wiki · 2026-08 · doc
- ThermaX PEEK — product page 3DXTech · 2026-08 · vendor
- Moisture Conditioning — effect on printed nylon properties Polymaker Wiki · 2026-08 · doc
- Fiberon PA6-CF20 Technical Data Sheet V1.1 Polymaker · 2024-12 · tds
- PolyMide CoPA Technical Data Sheet V5.4 (dry and wet status blocks) Polymaker · 2024-11 · tds
- FDM PA6/66-GF30-FR — Material Data Sheet Stratasys · 2026-07 · tds
- VICTREX AM 200 — FDM Material Data Sheet Stratasys · 2024-04 · tds
- TECAMID 66 GF30 black (PA66-GF30) — stock shape properties Ensinger · 2026-08 · tds
- TECAPEEK natural (PEEK) — stock shape properties Ensinger · 2026-08 · tds
- PEEK polymers — product overview Victrex · 2026-08 · doc
- Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments (Azimi et al.) Environmental Science & Technology 50(3) 1260-1268 · 2016-01 · paper
- Ultramid Nylon Chemical Resistance guide (unmodified PA6 B27E and PA66 A27E) BASF · 2026-08 · tds
- The Effects of Sulfonated Poly(ether ether ketone) Ion Exchange Preparation Conditions on Membrane Properties Yee, Zhang & Ladewig, Membranes 3(3) 182–195 · 2013-07 · paper
- Chemical resistance — resistance of Ensinger plastics to chemicals (DIN 50 014, 23/50) Ensinger · 2026-08 · tds
- What solvents are not compatible with PEEK? — fluidics technical FAQ IDEX Health & Science · 2026-08 · doc