Filament comparison
Conductive vs PP-GF
Compare printing settings, strength, heat resistance, dated prices and sources.
2 selected · all documented properties
| Property | Conductive filamentSPECIALTY | Glass-fibre PP (PP-GF)POLYOLEFIN |
|---|---|---|
| Market snapshot | ||
| Listing priceUSD/kg; dated snapshots | $170.36/kg median; $89.99–$796.00/kg across 4 dated product listings | $49.09/kg median; $46.27–$86.01/kg across 3 dated product listings |
| Identity & Market | ||
| Base polymer / chemistry | A carbon-filled compound conductive by volume rather than merely dissipative; Proto-pasta's is PLA-based, Recreus's and NinjaTek's are TPU, and add:north's Koltron G1 does not state its base polymer[1][2][3][4] | Polypropylene reinforced with chopped glass fibre[5][6] |
| Densityg/cm³ | Not documented | 1.12 (Prusament PP Glass Fiber, ISO 1183) — the glass lifts it above water[5] |
| Typical priceUSD/kg | 1 kg-equivalent spools span 90–181 for the carbon-filled grades; add:north's Koltron G1 sits far above at 796 because it is sold only in 100 and 250 g coils[7][8][9] | 1 kg-equivalent spools cluster near 49[10][11][12] |
| Price range across brandsUSD/kg | 90–796 across brands; Proto-pasta conductive PLA 90 at 1 kg, Recreus Conductive Filaflex 160 at 500 g, NinjaTek Eel 181 at 1 kg, add:north Koltron G1 796 at 250 g[7][2][8][9] | 46-86 across brands; BCN3D PP GF30 46 at 700 g, BASF Ultrafuse PP GF30 49 at 2.2 kg, Prusament PP Glass Fiber 86 at 850 g[10][11][12] |
| Market availability1–5 | Niche, a handful of specialist brands[7][2] | Available from several mainstream brands[10][11][12] |
| Spool sizes & diameters | 1.75 and 2.85 mm; 0.05, 0.1, 0.25, 0.5, 1 and 2 kg spools[7][2][8][9] | 1.75 and 2.85 mm; 700 g, 850 g and 2.2 kg spools[10][11][12] |
| Typical applications | Capacitive touch surfaces, low-current traces, EMI shielding and static-safe fixtures[1] | Stiff, chemically resistant parts where PP-CF's cost or conductivity is unwanted[6] |
| Diameter tolerance± mm | Not documented | ±0.04 (Prusament)[5] |
| Printing Parameters | ||
| Nozzle temperature°C | Not documented | 245 ± 10 (Prusament) — 25 °C below the carbon-fibre grade[5][13] |
| Bed temperature°C | Not documented | 95 ± 10 (Prusament)[5] |
| Enclosure / chamber requirement1–5 | Open frame is fine[1] | Enclosure recommended — Simplify3D lists an enclosure as a hardware requirement and Polymaker advises one below 70 °C ambient to stop warping and cracking[14][15] |
| Part cooling fan | Not documented | Off — Prusa runs 0 % except 100 % on bridges[5] |
| Maximum volumetric flow (mm³/s; see test conditions)mm³/s | Not documented | 4 at Prusa's 50 mm/s cap on a 0.4 mm nozzle at 0.2 mm layer[5][16] |
| Warping tendency1–5 | Not documented | High — enclosure needed for reliable large parts; Prusa recommends a brim[5] |
| Bed-adhesion difficulty1–5 | Not documented | Very difficult — special plates or slurry required[5] |
| Overall printing difficulty1–5 | Intermediate — dry filament and a tuned profile[1] | Advanced — enclosure, hardware upgrades, tuning; hardened nozzle mandatory[5] |
| Extruder requirement | Not documented | Prusa states a hardened nozzle is necessary and recommends a brim[5] |
| Hardware Wear & Reliability | ||
| Nozzle hardness required1–4 | Brass acceptable; hardened steel for volume work[1] | Hardened steel required[5] |
| Abrasiveness1–5 | Moderately abrasive — conductive carbon filler[1] | Highly abrasive — standard GF composite[5] |
| Nozzle clog risk1–5 | Low — Proto-pasta states the carbon-filled grade prints on standard PLA settings with no special nozzle required[1] | Moderate — needs dry filament and a clean nozzle; Prusa lists higher risk of nozzle clogging for glass-filled composites[17] |
| Moisture Behaviour | ||
| Moisture absorption (hygroscopicity)1–5 | Not documented | Low (0.1–0.3 %) — 0.11 % at both 24 h and 7 days, higher than the carbon-fibre grade's 0.04 % but still very low[5][13] |
| Equilibrium moisture content at ~50 % RH% | Not documented | 0.11 after 24 h and 0.11 after 7 days at 24 °C / 22 % RH (Prusa Polymers)[5] |
| Effect of moisture on strength | Polymaker rates PLA low-sensitivity and publishes no dry-versus-conditioned figures; absorbed water flashes to steam and shows as bubbling and poor layer adhesion[18] | Not applicable in practice at 0.11 % equilibrium uptake[5] |
| Storage requirement | Not documented | No special storage needed[5] |
| Mechanical Properties | ||
| Tensile strength (XY)MPa | Not documented | 46.6 ± 1.3 filament tensile yield (Prusament, ISO 527) — more than double the carbon-fibre grade's 21[5][13] |
| Charpy impact, notchedkJ/m² | Not documented | 7.9 ± 0.4 printed horizontal and 9.9 ± 0.8 printed vertical XZ (ISO 179-1, notched)[5] |
| Brittleness1–5 | Brittle — snaps with little warning; carbon-black loading at conductive levels embrittles PLA[1] | Moderate[5] |
| Hardness (scale-specific)Shore A / Shore D / Rockwell | Not documented | Rockwell R102 (and M95) on extruded unfilled PP stock (ASTM D785); no figure is published for a glass-fibre PP filament[19] |
| Elasticity / flexibility1–5 | Rigid[1] | Rigid[5] |
| Thermal Properties | ||
| HDT at 0.45 MPa°C | Not documented | 138.3 (ISO 75, 0.45 MPa)[5] |
| HDT at 1.8 MPa°C | Not documented | 112.6 (ISO 75, 1.8 MPa)[5] |
| Environment & Chemical | ||
| Chemical resistance | Not documented | Excellent against acids, alkalis and most solvents[15] |
| Water / humidity resistance in service1–5 | Not documented | Excellent — essentially unaffected[5] |
| Electrical & ESD properties | Conductive rather than dissipative — Proto-pasta sells the grade as electrically conductive composite PLA[1] | Not documented |
| Health & Safety | ||
| Fume toxicity1–5 | Low hazard — minimal VOC and particle emission; none of these materials was in the chamber study[20] | Low hazard — minimal VOC and particle emission. Inferred: no polyolefin was among the nine filaments in the Azimi chamber study, so this is a family-level judgement rather than a measurement[20] |
| Ventilation / filtration requirement1–5 | Open a window / occasional ventilation[20] | Open a window / occasional ventilation. Inferred — no polyolefin was measured in the chamber study[20] |
| Dust & fibre handling hazard | Conductive carbon filler is bound in the matrix; avoid inhaling sanding dust[1] | Glass fibre is bound in the matrix; avoid inhaling sanding dust[5] |
| Solvents & Solubility | ||
| Soluble in | Chloroform dissolves PLA-based grades, leaving the carbon black; TPU-based grades need DMF, NMP or THF. Laboratory reagents.[21][22] | None at room temperature; chloroform dissolves the matrix at 60 °C and xylene at about 118 °C, leaving the fibre.[23][24] |
| Softened or crazed by | Acetone and ethyl acetate plasticise a PLA-based grade; a TPU-based grade swells in toluene, esters and alcohols.[21][22] | Xylene, decalin, CCl4 and chlorobenzene are heavily absorbed at 20 °C; oleum, chlorosulphonic acid and bromine destroy it.[23] |
| Solvent welding & smoothing agent | None — neither PLA nor TPU has a workshop-safe welding or smoothing solvent.[21][22] | None — nothing softens PP at room temperature, so joints have to be welded thermally rather than chemically.[23] |
Material entries describe families or representative grades, not an interchangeable specification for every spool. Test methods, orientations and conditions may differ. Unknown values are marked “Not documented”. Prices and source dates remain historical snapshots; check the linked guide for product details. Differences highlight text, not a universal winner.
Sources for this comparison
- Electrically Conductive Composite PLA — product page and technical data Proto-pasta · 2026-08 · tds
- Recreus product catalogue Recreus · 2026-08 · vendor
- Eel 3D Printing Filament Technical Specifications NinjaTek · 2026-08 · tds
- Koltron G1 Technical Data Sheet add:north · 2026-08 · tds
- Prusament PP Glass Fiber Technical Datasheet v1.0 Prusa Polymers · 2024-11 · tds
- Prusament PP Glass Fiber — material page Prusa Polymers · 2026-08 · doc
- Proto-pasta product catalogue Proto-pasta · 2026-08 · vendor
- Eel product page — durometer, print guidelines and price NinjaTek · 2026-08 · vendor
- add:north Koltron G1 product page add:north · 2026-08 · vendor
- BASF Ultrafuse PP GF30 Black 2.85 mm 2.200 g igo3d · 2026-08 · vendor
- BCN3D PP GF30 Black 2.85 mm 700 g igo3d · 2026-08 · vendor
- Prusa Prusament PP Glass Fiber Natural (NFC), 1.75 mm / 850 g 3DJAKE · 2026-08 · vendor
- Prusament PP Carbon Fiber Technical Datasheet v1.0 Prusa Polymers · 2024-11 · tds
- Polypropylene — Ultimate 3D Printing Materials Guide Simplify3D · 2026-08 · doc
- PP — material basics Polymaker Wiki · 2026-08 · doc
- Max volumetric speed Prusa Knowledge Base · 2026-08 · doc
- Composite materials filled with carbon, kevlar or glass Prusa Knowledge Base · 2026-08 · doc
- Wet Filament — signs, causes and drying Polymaker Wiki · 2026-08 · doc
- TECAFINE PP natural — stock shape properties Ensinger · 2026-08 · tds
- Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments (Azimi et al.) Environmental Science & Technology 50(3) 1260-1268 · 2016-01 · paper
- Solubility Study of Ingeo Biopolymer Grades in Common Organic Solvents (NWPD003) NatureWorks · 2019-10 · tds
- Elastollan — Chemical properties: swelling and chemical resistance BASF · 2026-08 · tds
- Pro-fax and Moplen polypropylene — Chemical Resistance Guide (20, 60 and 100 °C) LyondellBasell · 2026-08 · tds
- US 5,278,282 Polymer recycling by selective dissolution — xylene dissolution temperatures Nauman & Lynch, Rensselaer Polytechnic Institute · 1994-01 · paper